Products

주요제품

Biocision  >  CoolRack® tube modules

CoolRack® tube modules

Thermo-Conductive Tube Modules

브랜드 Biocision
제품특징

CoolRack® thermo-conductive tube modules eliminate variability which originates from tubes placed directly into ice, dry ice, alcohol baths, water baths
and other temperature sources. Place the CoolRack module directly onto a temperature source between -196°C to >100°C and it will rapidly adapt to
that temperature. CoolRack modules ensure +/- 0.1°C temperature uniformity across all tubes when cooling, snap freezing, heating or thawing. Suggested applications include cooling reagents such as restriction enzymes, dNTPs and antibodies, alcohol-free dry ice snap freezing of tissue, virus and bacteria samples and bench top cryogenic tube sorting in liquid nitrogen. All CoolRack modules may be autoclaved, high heat sterilized or decontaminated
with bleach, alcohol or other disinfectants or lab detergents. Certain CoolRack modules are SBS-compatible.

제품스펙
Cat No. Description For Use With Wells Well Shape Dimensions (L x W x H) Well Dia Well Depth Row Spacing Column Spacing
BCS-163 CoolRack M6  

1.5 mL or 2.0 mL tubes

 

6

 

Cylindrical

 

6.0 x 4.3 x 3.8 cm

 

11.1 mm

 

32.7 mm

 

17.8 mm

 

17.8 mm

BCS-165 CoolRack M6, green
BCS-164 CoolRack M6, orange
BCS-125 CoolRack M15  

1.5 mL or 2.0 mL tubes

 

15

 

Cylindrical

 

10.2 x 6.4 x 3.8 cm

 

11.1 mm

 

32.7 mm

 

17.8 mm

 

17.8 mm

BCS-125G CoolRack M15, green
BCS-125O CoolRack M15, orange
BCS-127 CoolRack M15-PF 1.5 mL conical tubes 15 Conical 10.2 x 6.4 x 3.8 cm 11.1 mm 35.3 mm 17.8 mm 17.8 mm
BCS-535 CoolRack XT M24 1.5 mL 0r 2.0 mL tubes 24 Cylindrical 12.8 x 8.5 x 3.8 cm 11.1 mm 32.7 mm 17.8 mm 17.8 mm
BCS-539 CoolRack XT 5ml 5.0 mL centrifuge tubes 12 Conical 12.7 x 8.6 x 5.0 cm 16.5 mm 48.7 mm 28.0 mm 28.0 mm
BCS-108 CoolRack M30  

1.5 mL or 2.0 mL tubes

 

30

 

Cylindrical

 

12.0 x 10.2 x 3.8 cm

 

11.1 mm

 

32.7 mm

 

17.8 mm

 

17.8 mm

BCS-108G CoolRack M30, green
BCS-108O CoolRack M30, orange
BCS-128 CoolRack M30-PF 1.5 mL conical tubes 30 Conical 12.0 x 10.2 x 3.8 cm 11.1 mm 35.3 mm 17.8 mm 17.8 mm
BCS-137 CoolRack M30-PF 500ul 500 uL conical tubes 30 Conical 12.0 x 10.2 x 3.8 cm 11.1 mm 35.3 mm 17.8 mm 17.8 mm
BCS-102 CoolRack M90 1.5 mL or 2.0 mL tubes 90 Cylindrical 26.8 x 11.2 x 3.8 cm 11.1 mm 32.7 mm 17.8 mm 17.8 mm
BCS-116 CoolRack M96ID 1.5 mL or 2.0 mL tubes 96 Cylindrical 25.4 x 15.2 x 3.8 cm 11.1 mm 32.7 mm 17.8 mm 17.8 mm
주요사항
CoolRack®이 없을 때 CoolRack®이 있을 때
• 중구난방식의 샘플 나열

• Label이 젖는 단점

• Contamination의 risk

• 일정하지 않은 sample 온도

• Non-reproducible Method

• 일정한 sample 나열

• Dry한 상태로 sample label의 보호

• 일정한 sample 온도 (<4℃)

• Reproducible Method